欢迎光临贵州源妙自动化设备有限公司官网!
工控设备卡件 | 工业自动化主营:PLC系统 DCS系统 伺服系统 机器人系统
全国咨询热线:15339539190
联系我们
贵州源妙自动化设备有限公司
手机:15339539190
QQ:3598571032
邮箱:18000000002
地址 :贵州省安顺市西秀区北街街道虹山湖路42号虹山大酒店(百灵.希尔顿逸林酒店 )幢14层9号(电梯楼17层)
联系人:程明绒
您的位置: 首页>>产品展示 >
产品展示 》 HIMA黑马 》 Z7306

Z7306

型号:Z7306

联系人:程明绒
公司名称:贵州源妙自动化设备有限公司
公司地址:贵州省安顺市西秀区北街街道虹山湖路42号虹山大酒店(百灵.希尔顿逸林酒店 )幢14层9号(电梯楼17层)
手机:15339539190
QQ:3598571032
邮箱:18000000002

下单请联系我们:程程15339539190(微信同号)QQ3598571032邮箱3598571032@.COM,欢迎咨询。注;本站所有产品均为特殊产品,市场价格一直波动,具体以客服报价为准,因产品为全新产品,图片并非实拍,下单前请跟客服确认型号和产品,价格等详细信息,网站内二手,全新均有销售,具体请联系客服沟通。
 Z7306

采购美国、德国、法国、意大利等欧盟工控产品、备品备件

In order to ensure safety production and realize emergency treatment of emergency accidents, the external automatic tracking regulator is installed on the six regulator circuits. In case of control system failure, the tracking regulator is automatically switched to control the regulating valve independently of DCS; 21 main valves are equipped with emergency treatment button, which is independent of DCS to realize forced switch on the valve. 2.3. hardware configuration:Omron C200 PLC is selected in the control station, and 9 digital modules (od211/ id212), 4 analog modules (ad003) and 3 regulating modules (pid03) are configured; The operation station adopts Dell opt gx150 computer; The engineer station adopts compa PC. The composition is as follows:2.4. software configuration of control station:The configuration of control station is based on the system software SSS of OMRON as the technical platform and ladder diagram as programming tool. The configuration contents are as follows:2.4.1.allocation of PLC internal address:I/o address distribution: the i/o address of PLC is the only one-to-one register address for data communication between PLC and field detection equipment and actuator. The allocation of i/o address is the basis for further configuration of PLC; For omron-c200, i/o address is related to the connected i/o module; The i/o address of the field equipment connected to the digital module depends on the installation position and the point number on the module. The i/o address of the field equipment connected to the analog module and PID module depends on the unit number of the i/o module (different modules shall be set with different unit numbers through the hard opening and closing of the module) and the point number on the module; For example, in the configuration of this system, the analog signal of 4-20mA output by the radar level transmitter LT-101 on site is connected to the second point of analog input module ad003 with unit number 3, the address of its configuration in PLC is ir:132; When the closed signal of valve hv120 is connected to the tenth point of the digital input module id212 installed in the second slot of the expansion rack, its configuration address in PLC is ir:01210; In this system, 142 i/o addresses are defined.
Z7306

在线客服
联系方式

热线电话

15339539190

上班时间

周一到周五

公司电话

15339539190

二维码
线